VARIOKLAV® Module options

Module options allow our HP Medizintechnik VARIOKLAV autoclaves
to be configured for a variety of specialized sterilisation tasks and
process requirements.


 

 

 

Fast cooling

HP_Med_VARIOKLAV_Laborautoklaven_2011_Seite_10_Bild_0001


High throughput liquid and culture media sterilisation

The fast cooling modules dramatically shorten autoclave cooling times, enabling greater throughput in batch processing applications. Cooling times are reduced to between 5 and 80 minutes, depending on procedure, vessel size and autoclave load.

  • Media temperature control MT: Highly flexible, robust media probe for precise control of sterilisation time
  • Easily exchangeable in the case of service
  • Monitoring of sensor break and short circuits
  • Cooling water consumption: 15 to 40 litres

 

 

RM rapid cooling module
for sterilisation of liquids in open vessels

  • Integrated stainless steel water jacket provides cooling without reducing autoclave capacity
  • Media temperature control MT and media temperature sensor included
  • Cooling times reduced by up to 40%
  • Advantageous for thermally unstable media, adjustable withdrawal temperature

 

Module Order No.
RM rapid cooling module (open)**
51900801
 ** Including media temperature control MT

 

 

 

RG rapid cooling module
for sterilisation of liquids in open and hermetically-closed vessels

  • Integrated stainless steel water jacket, ventilator fan and counter pressure system with sterile compressed air
  • Media temperature control MT and media temperature sensor included
  • For rapid, secure cooling of pressure-tight closed vessels, too
  • Ultra-fast cooling times for open and lightly closed vessel sterilisation
  • Advantageous for thermally unstable media, adjustable withdrawal temperature

 

Module Order No.
RG rapid cooling module* ** (open, closed) 51900803
 *  Not available for VARIOKLAV 25 T
 ** Including media temperature control MT

 


 

 

 

Pre-vacuum and drying

HP_Med_VARIOKLAV_Laborautoklaven_2011_Seite_11_Bild_0001

Sterilisation of waste, solids and porous material

Integrated pre-vacuum module for VARIOKLAV autoclaves ensure safe sterilisation of porous materials and items that are difficult to deaerate. An additional module with post-vacuum allows the unloading of materials in a dry state.

• Wrapped instruments (container, fleece)
• Tubes, syringes, pipettes, pipette tips in boxes
• Waste in bags (in combination with emission free sterilisation)
• Textiles, filter candles and plates
• Equipment and materials with hollows or cavities
• Glass and working equipment

 

VF module fractionated pre-vacuum
for thorough deaeration before sterilisation

  • Single pre-vacuum or fractionated pre-vacuum cycle completely removes atmosphere to enhance steam penetration and improve the sterilisation quality
  • Adjustable vacuum levels and pressure cycling allows economic processes for complete deaeration

 

Module Order No.
VF fractionated pre-vacuum module* (including single vacuum program) 51900805
   

 

 

 

VT module vacuum drying
prevents re-contamination after sterilisation

  • After-sterilisation, deep vacuum drying with powerful double wall heating eliminates moisture
  • Chamber is uniformly heated from the outside, followed by sterile venting to prevent re-contamination

Modell Art.-Nr.
VT fractionated pre-vacuum and vacuum drying module with sterile ventilation* 51900807
*Not available with VARIOKLAV 25 T  

 


 

 

 

Emission-free sterilisation


Hazardous material sterilisation

Our VARIOKLAV autoclaves are available with exhaust-air filtration and condensate sterilisation.

This enables safe, emission-free sterilisation of hazardous biological materials and media, including pathogens, infectious agents and genetically engineered samples. Both the external atmosphere and waste-water drainage system are protected from contamination.

  • Sterile disposal of potentially infectious laboratory waste in risk group 2 to 4
  • Sterile disposal of genetically modified material from 2 to 4 security level laboratories
  • Safe sterilisation of infectious material or pathogens from the clinical area
  • Steam heated double jacket made of stainless steel enables exact temperature control of the sterilisation chamber
  • Short steam paths ensure complete sterilisation including the filter
  • Easy-to-exchange filter, ensures sterility after each use, not penetrated by sprout
  • Can be combined with cooling modules as well as vacuum and drying processes

 

FA module for exhaust-air filtration
with condensate sterilisation
for safe sterilisation of hazardous materials

  • Aerosols contained in exhaust air are retained by a filter prior to sterilisation
  • Simultaneous sterilisation of chamber contents, collected condensate and filter housing
  • Sterilisation chamber with bottom respectively back are evenly steam heated from outside
  • Drain valve in the chamber floor has no inaccessible spaces and thereby guarantees a complete sterilisation and removal of the condensate
  • Safety shut-down in the event of supply media failure or program termination before sterilisation cycle

Module Order No.
FA module for exhaust-air Filtration with condensate sterilisation*
51900809
Exhaust air filter cartridge DN 15, 0,2 μm on request
* Not available for VARIOKLAV 25 T and 65 T 


 

 

 

Process documentation


Sterilisation cycle traceability

Integrated printers for VARIOKLAV autoclaves provide a compliant hard copy of batch process parameters.

• E.g. for the documentation of validated processes
• The built in pressure and temperature sensors are still adjustable
• Printing on normal paper
• Print-outs have a shelf life of at least 10 years
• RS 232 and USB interface for process documentation via SegoSoft

 

GLP batch printer
for compliance through simple data recording

  • Process steps, start/stop times, chamber/reference temperatures,
    chamber pressure and any alert alarms are registered
  • Records digitally process data of the controller
  • Recommended for routine procedures and security level 2 laboratories

Module Order No.
GLP batch printer 51900810
Extension Order No.
Software SegoSoft for process documentation 50085028

 

GMP batch printer
for compliance through the
independent measuring system I-M-S

  • Process steps, start/stop times, chamber/reference temperatures,
    chamber pressure, and any alert alarms are registered
  • Temperature and pressure data from independent reference sensors
    calibrated to ISO 9000 standards are registered and displayed
  • Recommended for demanding applications, pharmaceutical manufacturing and risk group 3 waste

Module Order No.
GMP batch printer for the independent measuring system I-M-S * 51900811
Extension Order No.
Software SegoSoft for process documentation 50085028
* Not available with VARIOKLAV 25 T 

 



Extensions >>


 